Home | Site Map | Contact Us |

Phase Technology CPA-T30 Portable Cloud Point Analyzers

Convenience, ease-of-use, and quick, precise test results – all in a small, portable package that makes it the most affordable cloud point analyzer available.

The CPA-T30 is an ideal quality control tool for fuel distributors, truck fleets, biodiesel producers and users, terminals, pipelines, military, educational and R&D labs.

 

Cost-saving Benefits With Big Payoffs

  • Reduce fuel cost – ensure proper blending ratio of diesel and biodiesel to meet climate requirements
  • Prevent downtime – accurate cloud point information prevents possible fuel gelling.
  • Blending support – on-screen “blends” function calculates approximate volume ratio of two fuels to mix together to obtain a target cloud point.
  • Optimize additives – add sufficient amount to meet current weather conditions without overdosing
  • Monitor fuel quality – added checkpoint for quality control of product and suppliers

Precision & Portability at an Economical Price

  • Unsurpassed precision — repeatability as low as 0.4 ºC, reproducibility as low as 0.5 ºC
  • Super fast speed — diesel test results in just 3 - 5 minutes
  • Compact, portable design — goes anywhere, lab or field
  • Completely self-contained system — plug into electricity, or use optional cigarette-plug adapter or rechargeable battery
  • Incredibly simple to use — intuitive, touch-sensitive LCD touch screen — just load the sample, touch the “START TEST” button and the analyzer does the rest

ASTM Method

ASTM International recently approved a new standard that covers the determination of the cloud point of petroleum and biodiesel fuels. The standard, D7397, was developed based on Phase Technology’s patented technology and used exclusively in our CPA-T30 portable cloud point analyzer.

ASTM D7397 and D5773 (as used in Phase Technology CPA-T30 and 70X analyzers) are the only automatic methods for determining cloud point allowed in ASTM D6751, the specification used to control pure biodiesel (B100) quality prior to blending with conventional diesel type fuels.

ASTM D7397 and D5773 are included as methods for determining cloud point in ASTM D7467, the specification that covers finished fuel blends of between six (B6) and twenty (B20) percent biodiesel for on- and off-road diesel engine use.

Specifications

STANDARD TEST METHODS

Cloud Point:

ASTM D7397
STATED PRECISION: REPEATABILITY
and REPRODUCIBILITY
Repeatability: as low as 0.4ºC
0.8ºC typical
Reproducibility: as low as 0.5ºC
1.1ºC typical

SAMPLE TEMPERATURE RANGE

-40ºC to 20ºC

TEST RESOLUTION

-0.1ºC

TEST DURATION

3 - 5 minutes

REQUIRED OPERATOR TIME

0.5 minutes

SAMPLE SIZE

30 mL

DETECTION METHOD

Diffusive Light Scattering (DLS) technology (over 25 patents)

COOLING SYSTEM Integrated Peltier device cooling system
DISPLAY 3.25” (8.3 cm) LCD touch screen
TEMPERATURE MEASUREMENT ºC or ºF (User selectable)
INTERNAL MEMORY Storage up to 100 test runs
AMBIENT OPERATING ROOM TEMPERATURE 10°C to 30°C
DIMENSIONS
(W X D X H)
10 x 5.5 x 5 inches
25 x 14 x 13 cm
WEIGHT 3 lbs (1.3 kg)
UTILITY REQUIREMENTS Electrical: 100 – 240 VAC, 50 – 60 Hz
or 12 VDC input

Applications & Options

The CPA-T30 is designed to test the cloud point of middle distillate fuels. These typically include light to middle distillate Number 1 or 2 fuels, biodiesel and biodiesel blends intended for light- or heavy-duty diesel engines.

For operability purposes and adequate cold weather protection, the diesel cloud point should be a minimum of 7 °F (approximately 4 °C) below the lowest anticipated ambient temperature that the fuel is expected to operate. For biodiesel, a minimum 10 °F (approximately 6 °C) difference